Ventless ambient gas log set liquid propane 28 000 btu model vf18la 2.
Ventless propane wall heater troubleshooting.
Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt.
For screen reader problems with this website please call 1 800 430 3376 or text 38698 standard carrier.
Blow air through the ports slots and holes in the burner.
It should be about one inch high and mostly blue.
Dyna glo 30 000 btu vent free infrared liquid propane thermostatic wall heater model irss30lpt 2p 227 78 227 78.
Spray compressed air into the all of the burner s holes.
Customers may experience pilot outages and performance problems with the product.
If windows are not left partially open to ensure ventilation or if you fail to install a carbon monoxide co detector that has a battery backup occupants of the home may sleep through a device malfunction and never wake up.
Free the ignitor cable of your heater from kinks or pinches if you do not see a spark from the.
Procom 30 000 btu blue flame ventless dual fuel heater with base and blower model mnsd300tba bb 189 99 189 99.
Procom heating 18 in.
Open the heater s access panel.
If there is or your heater runs on natural gas check the handle on the gas line.
Vacuum out the inside of the panel to remove dust and dirt.
Allow the unit to cool for at least 30 minutes.
The pilot should be around an inch high and mostly colored blue.
Procom does not guarantee their vent free products to operate correctly above 4500 ft.
If your propane heater has a standing pilot you should be able to see it through a window or opening under the gas control knob.
Most propane heater problems can be traced to a malfunctioning pilot.
If you have a propane tank make sure there s gas in it.
Shut off the ventless gas heater s power and allow it to cool for 30 minutes or more.
How do i troubleshoot a comfort glow lp heater.
Light your comfort glow heater by pressing the ignitor button if you find yourself looking for a way to light the pilot do not try to.
If your propane heater has a standing pilot you should be able to see it through a small window or opening near the control knob.
Using a ventless catalytic propane heater to warm your home is a dangerous proposition.
Check the injector holder located at the end of the burner tube.
For screen reader problems with this website please call 1 800 430 3376 or text 38698 standard carrier rates apply to texts.
It should be parallel to the pipe.
Vent free also known as ventless heating does not require ventilation.